Air conditioner sizing means matching the cooling capacity of a unit to the heat that actually enters a room. That heat load depends on floor area and ceiling height, but even more on window size and orientation, shading, insulation, the number of people, and heat from appliances and lighting. In Switzerland capacity is given in kilowatts (kW); in some brochures you will still see BTU per hour (1 kW is about 3,412 BTU/h). A unit that is too small runs at full power without reaching the set temperature. A unit that is too large cools quickly, switches off, and leaves the air damp and the room uncomfortable. A proper sizing calculation, room by room, avoids both problems.

kW, BTU and what the label means

Manufacturers state a nominal cooling capacity in kW, measured under standard conditions. Inverter units can modulate below and above that figure. When comparing units, look at the nominal capacity and the range. BTU/h figures are common in English-speaking countries; divide by about 3,412 to get kW. Do not confuse cooling capacity with electrical power consumption, which is much lower.

What drives a room’s cooling load

Factor Effect
Window area and orientation Large south- or west-facing windows add a lot of heat
Shading External shutters or awnings cut solar gains dramatically
Insulation and roof Top floors under a poorly insulated roof heat up more
Occupants Each person adds heat
Appliances and lighting Computers, TVs, ovens add internal gains
Room volume High ceilings increase the air volume to cool

Why rules of thumb are risky

Simple formulas based on watts per square metre are popular, but they ignore the factors that matter most. A north-facing bedroom with shutters and a sun-drenched living room with a glass wall can have the same floor area and very different loads. In Ticino there is no general capacity limit per square metre, but systems must meet the cantonal energy requirements, so oversizing is both inefficient and harder to justify. Our article on air conditioning rules in Switzerland explains the background.

The problem with oversizing

  • Short cycling: the unit reaches the set temperature quickly and switches off, then on again.
  • Poor dehumidification: short run times remove less moisture, so the room feels clammy.
  • Lower efficiency and more wear: frequent starts are hard on the compressor.
  • Higher purchase cost for no comfort gain.

The problem with undersizing

  • The room never reaches the set temperature on hot afternoons.
  • The unit runs at maximum speed, which is noisier.
  • Users lower the set point further, which does not help.

How a proper calculation works

  1. Measure each room: area, height, windows, orientation.
  2. Note shading devices and insulation.
  3. Estimate occupancy and internal gains.
  4. Calculate the peak cooling load per room.
  5. Choose units whose modulation range covers both peak and typical loads.
  6. Check against the cantonal rules and noise requirements for the outdoor unit.

Reduce the load before buying capacity

The cheapest kilowatt of cooling is the one you do not need. Closing external shutters during the day, ventilating at night, replacing old halogen bulbs and keeping heat-producing appliances out of bedrooms all reduce the load. In many Ticino homes, good shading alone makes a smaller unit sufficient.

Multi-split systems

With a multi-split, each indoor unit is sized for its room, and the outdoor unit for the combined load. Because not all rooms peak at the same time, the outdoor unit can sometimes be smaller than the sum of the indoor units. This needs careful planning by the installer. The cost implications are covered in air conditioning installation cost.

Example: two bedrooms in Locarno

An apartment has a west-facing bedroom with a large window and a north-facing children’s room. The owner initially wants two identical units. The calculation shows that the west room needs noticeably more capacity in the afternoon, while the north room needs very little. The installer proposes two different indoor unit sizes on one outdoor unit, plus closing the shutters in the afternoon. Both rooms reach a comfortable temperature without short cycling.

Common mistakes

  • Choosing capacity by floor area alone.
  • Buying “one size up to be safe”.
  • Ignoring shading and solar gains.
  • Forgetting the cantonal energy requirements.

Frequently asked questions

Is a bigger air conditioner faster at cooling?

It reaches the set temperature faster, but often at the expense of humidity control and efficiency.

How do I convert BTU to kW?

Divide the BTU/h figure by about 3,412. For example, 9,000 BTU/h is roughly 2.6 kW.

Can one unit cool a whole apartment?

Rarely well. Air does not move easily between rooms, so each room that needs cooling usually needs its own indoor unit.

Correctly sized air conditioning

AcquaKlima Sagl calculates the load room by room and installs correctly sized systems across Ticino. Learn more about air conditioning or get in touch.

From the blog

Need a quote or a call-out?

Call us or message us on WhatsApp: we reply in Italian, French, German and English.