24/7 on call

To replace an oil boiler with a heat pump, follow clear stages: assess the house and existing heating, calculate the heat demand and required flow temperature, compare options (air-source or ground-source), check cantonal rules and apply for subsidies, then plan the installation, including removal of the boiler and oil tank. After installation, the system should be fine-tuned during the first winter. Most houses with radiators can switch to a heat pump, sometimes after enlarging a few radiators and balancing the system. Planning ahead, ideally while the old boiler still works, avoids a rushed decision in mid-winter.

Stage 1: assess before you replace the oil boiler

  • Annual oil consumption over several years.
  • Type and size of radiators or underfloor heating.
  • Insulation and planned renovations.
  • Space for the outdoor unit or a borehole.
  • Hot water production and electrical supply.

Stage 2: heat demand and flow temperature

A heat pump works best at low flow temperatures. A simple test before the switch: lower the boiler’s heating curve step by step during a cold period and see which rooms get cool first. These rooms show where radiators may need upgrading. The installer calculates the heat demand and sizes the heat pump accordingly, rather than copying the oil boiler’s output.

Stage 3: choose the heat pump system

Option When it fits
Air-source heat pump Most houses in milder areas; space for an outdoor unit
Ground-source heat pump Where drilling is allowed; colder locations; no outdoor unit wanted
Hybrid (heat pump plus boiler) Transitional solution in special cases

Stage 4: rules and subsidies

In Ticino, cantonal rules apply when replacing a heat generator in an existing residential building, and a heat pump meets the renewable energy requirement. A notification or permit to the municipality is usually required, plus a noise assessment for air-source units and a drilling permit for boreholes. Apply for subsidies before ordering; see heat pump subsidies in Ticino.

Stage 5: installation

  1. Removal of the oil boiler.
  2. Cleaning and removal or decommissioning of the oil tank by a specialist.
  3. Installation of the heat pump, hot water tank and hydraulics.
  4. Electrical connection and controls.
  5. Radiator upgrades and hydraulic balancing.
  6. Commissioning and handover with instructions.

The best time is between spring and early autumn, when the heating can be off for a few days.

Stage 6: the first winter

A new system is rarely perfect from day one. During the first winter, observe comfort and consumption, and have the installer adjust the heating curve. Many systems can run at lower flow temperatures than first set, which improves efficiency. A check after the first winter is worth scheduling.

The oil tank

The oil tank must be emptied, cleaned and removed or decommissioned according to the rules by a specialist company. Remaining oil can sometimes be used up beforehand or taken back. The freed space can be used as storage.

Hot water

With a heat pump, hot water is usually produced in a new tank heated by the heat pump. Hot water hygiene depends on the temperatures at the different points of the system (tank, outlet, circulation loop and tap), on how often the water is renewed and on correct operation. The settings are defined by the installer for your configuration and the applicable rules: a periodic high-temperature cycle does not replace these conditions. The Swiss boiler article explains the background.

Costs and planning

The investment depends on the type of heat pump, the adaptations needed and the removal work. See heat pump cost in Switzerland for a breakdown of the main factors.

Example: house in Losone

A family with a 30-year-old oil boiler starts planning in winter. The installer calculates the heat demand, and a lower heating curve test shows that only the living room needs a larger radiator. A subsidy is approved in spring. In June, the boiler and tank are removed, an air-source heat pump is installed and the system balanced. After the first winter, the heating curve is lowered further.

What changes in daily life

With a heat pump, there are no more oil deliveries, no burner noise and no chimney sweep for the heating. The system runs more steadily, often with long periods of low output rather than short bursts. Radiators feel less hot to the touch but keep the rooms warm. Thermostatic valves should stay mostly open, and the room temperature is set mainly through the heating curve. Many owners appreciate the quieter boiler room and the freed space where the tank used to be.

Common mistakes

  • Waiting until the boiler fails.
  • Sizing from the oil boiler output.
  • Skipping hydraulic balancing.
  • Never adjusting settings after installation.

Frequently asked questions

Do I need underfloor heating for a heat pump?

No, many houses with radiators work well, sometimes after selective upgrades.

How long does the switch take?

Installation usually takes days to a couple of weeks; planning and approvals take longer.

What happens to the chimney?

It is no longer needed for heating; it can be closed or used for other purposes.

Switching to a heat pump

AcquaKlima Sagl guides you from assessment to the first winter across Ticino. Learn more about heating and heat pumps or get in touch.

From the blog

Need a quote or a call-out?

Call us or message us on WhatsApp: we reply in Italian, French, German and English.