Heat pumps work in cold weather, including well below freezing, but their efficiency falls as the outdoor temperature drops, because the compressor has to lift heat over a larger temperature difference. Air-source units also need to defrost their outdoor coil from time to time, which briefly interrupts heating. A correctly sized system covers the coldest days of the local climate, sometimes with a small electric backup heater for rare extremes. In the mild lakeside areas of Ticino, air-source heat pumps work under favourable conditions; in colder, higher valleys, careful sizing or a ground-source system becomes more important.

Why efficiency drops in the cold

A heat pump moves heat from a cold source to the warmer heating water. The bigger the gap between outdoor air and the required flow temperature, the more electricity it needs per unit of heat. On a mild day, an air-source heat pump delivers several units of heat per unit of electricity; on a freezing day, fewer. That is why the seasonal performance, not the performance on the coldest day, determines running costs.

Defrost cycles

When the air is cold and humid, ice forms on the outdoor coil. The heat pump detects this and defrosts briefly, usually by reversing the refrigerant flow. You may see steam rising from the unit and hear a short hiss. This is normal. Frequent or very long defrosts can indicate a dirty coil, poor airflow or a settings issue.

Lakeside versus valley

Location Typical conditions Implication
Lakeside (Locarno, Ascona, Gambarogno) Mild winters, few very cold days Air-source heat pumps work efficiently
Lower valleys Colder nights, fog, humidity More defrosting; size carefully
Higher valleys and mountain villages Longer frost periods, snow Ground-source or carefully sized air-source; snow protection

Backup heaters

Many air-source heat pumps have an electric heating element as backup. It helps on extremely cold days or during hot water hygiene cycles. Because it uses electricity directly, it should run rarely. If it runs often, the heat pump may be undersized, the settings may be wrong, or the flow temperature is too high. Check the operating data or ask the installer.

Sizing for the coldest days

The installer sizes the heat pump using the design outdoor temperature for your location and the building’s heat demand. Oversizing leads to frequent cycling in milder weather; undersizing means more backup heater use. A good design finds the balance and may accept a small amount of backup on the very coldest days.

Flow temperature matters most

The lower the flow temperature your radiators or underfloor heating need, the better the heat pump copes with cold weather. Hydraulic balancing, larger radiators in critical rooms and a correctly set heating curve all help. See replacing an oil boiler with a heat pump for how this is handled during a switch.

Outdoor unit in winter

  • Keep the unit clear of snow and leaves.
  • Make sure defrost water can drain freely and does not freeze into a block of ice.
  • In snowy areas, mount the unit on a raised base or bracket.
  • Do not cover the unit; it needs free airflow.

Ground-source in colder locations

A ground-source heat pump draws heat from a borehole, where the temperature remains fairly stable all year. It does not need to defrost and has no outdoor unit. In colder locations, this can make a significant difference to efficiency and comfort, although installation costs more. The cost aspects are covered in heat pump cost in Switzerland.

Example: house in the Maggia valley

An owner in a village in the lower Maggia valley wants to replace an oil boiler. The design temperature is lower than on the lake, and fog is frequent in winter. The installer sizes an air-source unit with care, places it on a raised base protected from snow, and ensures defrost water drains away. Two radiators are enlarged to lower the flow temperature. In the first winter, the backup heater runs only on a handful of very cold days.

Common mistakes

  • Sizing without considering the local design temperature.
  • Ignoring how often the backup heater runs.
  • Placing the outdoor unit where snow or ice accumulates.
  • Running high flow temperatures unnecessarily.

Frequently asked questions

Will my heat pump stop working at very low temperatures?

Modern units operate well below freezing. Efficiency is lower, and the backup heater may help on extreme days.

Is steam from the outdoor unit a problem?

No, it is normal during defrosting.

Should I lower the temperature at night in winter?

With heat pumps, large night setbacks are often counterproductive; moderate, steady operation is usually better.

Heat pumps for every location